The SpectraMax® ABS Microplate Reader bridges the gap between the affordability of filter-based readers and the . Specifications for the SpectraMax L microplate reader. The Analyst®, FlexStation® and SpectraMax® M5/M5 e from Molecular Devices have received the LanthaScreen® Certified designation from Life Technologies which ensures that these readers are validated to strict standards in instrument setup and assay performance. NOTE: Limited support and literature is available for the SpectraMax 250 due to the senescence of the product. The Spectramax 190 has an array of data collection modes, including kinetic, endpoint, and spectral scan modes. Molecular Devices SpectraMax 340PC384 Microplate Reader $ 4,000. Plate chamber design of the SpectraMax category 1 microplate readers. #0200-7009) VersaMax, SpectraMax 340PC384, 190, Plus 384 Microplate Readers User Guide Electromagnetic Compatibility Regulatory for Canada (ICES/NMB-001:2006) This ISM device complies with Canadian ICES-001. The SpectraMax Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. ¨SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Page 1 ® SPECTRAmax Microplate Spectrophotometer Operator’s Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0085 Rev. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader s with all leading partner robots. Published Dec 16, 2020 | Updated Dec 16, 2020. Select the Driver tab and click Update Driver. SpectraMax and VersaMax . Materials. Validating the absorbance optical performance of your microplate reader is as simple as reading a plate. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. The SpectraMax iD5 Multi-Mode Microplate Reader has been validated for use with the ValitaTiter and ValitaTiter. 300 µL of Detergent Compatible Bradford reagent was added to each well. 200. 195: G1–G3. per Spectramax reader, plus another 300 W for the Computer. D Contact Us Phone: +1-800-635-5577 Web: Email:[email protected]). Cell viability는 세포막 Integrity 또는. Optimal instrument settings are the same for all three readers. The Spectramax 190 absorbance microplate reader utilizes a patented multichannel optical design to simulate a dual beam spectrophotometer to help eliminate errors through the usage of a dual fiber optic exposure. Perform the following steps to install the drivers: Start > Control Panel > System. Molecular Devices announced today the launch of the new SpectraMax ® ABS and ABS Plus Microplate Readers that cover a wide range of absorbance-based applications such as ELISAs, microbial growth, and protein quantitation and can be easily integrated into full robotic systems. The value for 1000 should be higher than the value for 900. Molecular Devices provides the complete solution covering the instrument and software: • SpectraTest ABS1, FL1, and LM1 Validation Plates for. 0) at 37 °C, fluorescence intensity was recorded on a Spectramax M5 Multimode plate reader (Molecular Devices, USA) at each timepoint. 0. UV/Vis Photometric Performance:. SoftMax Pro. The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. Data collection and analysis are performed using a Melamine ELISA preconfigured protocol in SoftMax® Pro GxP Software, an industry-standard analysis software for FDA 21 CFR Part 11 compliance. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. SpectraMax Gemini EM & FLEXstation (bottom read) 1. 0200-6263. 3) This. This assay kit is optimized for the SpectraMax ® i3x Multimode Microplate Reader with a preconfigured protocol in SoftMax ® Pro Software for rapid data analysis. We would like to show you a description here but the site won’t allow us. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. Accurate measurements are ensured by automaticWide photometric range Temperature-regulated Thermal control and vertical shake Microsoft Windows-based software Automatic mixing Five-second read per plate Photometric and kinetic analysis mode The Molecular Devices ThermoMax is an efficient, temperature-regulated, 96 well microplate reader. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. The plate. 996 (n = 3) ; for SpectraMax Plus 384 reader, r 2 = 0. Molecular Devices SpectraMAX 190 Microplate Spectrophotometer Read more. SpectraMax® M2e Multi-Mode Microplate Reader (top and bottom reading) MLDVM2E SpectraMax® M3 Multi-Mode Microplate Reader MLDVM3 Ordering information VWR cat. Three low volume 24-well bottom slides. Fluorescence Microplate Reader Comparison Chart. Manufacturer: Molecular Devices; Model: SpectraMax 190; The Molecular Devices SpectraMax 190 Absorbance Microplate Reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temper. Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. Superior flexibility The SpectraMax i3 Multi-Mode Platform comes with When connecting for the first time to either the SpectraMax L reader or StakMax system. begin reading microplates with seven mouse clicks. ©2013 Molecular Devices, LLC | 10/13 | Printed in USA | PN: 0120-1526. What is the minimum well volume needed to run a 384 well plate? Minimum volume depends on the solution (curved vs. The Gemini XPS Reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. SpectraMax® iD3, iD5, ABS, and ABS Plus readers, and up to 2. If the computer is connected to the Internet: Select Search Automatically for. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual iii Labor and Parts To obtain warranty service during the applicable warranty period, you must take the product or de-liver the product properly packaged in the original shipping materials and carton to an authorized Molecular Devices Corporation service facility. It has a larger impact when measuring ODs above 2. Patents:. The cycle is then repeated indefinitely until the shaking stops. 190-840nm. SpectraMax Glo Steady-Luc Reporter Assay Kit, Molecular Devices (Explorer kit #R8352 or Bulk kit #R8353) Competitor kit: Steady-Glo Luciferase Assay System, Promega (Cat. 384 wells: 29 Seconds. Typically the system can detect absorbance, luminescence, fluorescence, and even make more specialized fluorescence measurements like time-resolved fluorescence (TRF) and fluorescence polarization (FP). Materials. Page 2 2) All labor charges to repair the product for a period of one (1) year from the original date of delivery will be paid by Molecular Devices Corporation. The calculated LOQ values were 0. degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. 2. Stray light. Detection cartridge modularity allows for easy addition of new read modes within minutes without. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. The carriage moves back-and-forth at 19. VersaMax™ SpectraMax® 190. Additionally, the SpectraMax 190 Microplate Reader can be seamlessly integrated with the StakMax Micropate Handling System through the. CMax Pro软件既可以控制仪器也可进行数据分析,如:线性拟合、四参数拟. 0 OD for earlier models. . ATP standard curves read on SpectraMax microplate readers. Temperature control. Devices’ StakMax® Microplate Stacker in a matter of minutes and . Microplate Reader Shelf. The SpectraMax ® iD5 Multi-Mode Microplate Reader includes an absorbance detection mode optimal for protein quantitation assays. The EMax® Plus Microplate Reader is designed to be a versatile and robust microplate reader for research laboratories. For a higher . With optimized reagents and the industry leading data acquisition and analysis tool, SoftMax® Pro 7 Software, the SpectraMax to perfectly match your needs. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR. The plate was incubated for 10 minutes at room temperature and read at 595 nm on the SpectraMax ABS Plus reader. The SpectraDrop microplate was read on the SpectraMax ® Paradigm ® Multi-Mode Microplate Reader using the Fluorescence Intensity detection cartridge (FI-FLRH) with fluorescein filters, or Tunable Wavelength Selection (TUNE) cartridge with signal/ background-optimized wavelengths. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. For SpectraMax ABS Plus reader, r 2 = 0. SoftMax Pro Software allows you to set up and run a complete protocol for the SpectraMax Multi-Mode Microplate Reader, as well as all other Molecular Devices' microplate readers. 00. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. The SpectraMax i3x Multi-Mode Microplate Reader has been validated for use with the ValitaTiter and ValitaTiter Plus assays. The 1/absorptivity value for double stranded DNA at 260 nm is commonly assumed. 과 같은 Parameter를 검사하여 평가할 수 있습니다. 997 (n = 3). SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual iii Labor and Parts To obtain warranty service during the applicable warranty period, you must take the product or de-liver the product properly packaged in the original shipping materials and carton to an authorized Molecular Devices Corporation service facility. 00. The SpectraMax i3x Multi-mode microplate reader. What is h the bandwidth for SpectraMax® plate readers and how do we determine it? The instrument bandwidth for the reader is expressed as half-bandwidth, meaning the full bandwidth at 1/2 the transmission peak for the selected wavelength. Infinite 200 Pro Microplate Reader. 5 mm (bottom read) Beam diverges to focal spot near bottom of well. microplates or in a cuvette at a. SpectraMax ABS Plus Microplate Reader. Instruments. Our SpectraMax microplate readers and SoftMax Pro software are the industry's most cited and have empowered life science researchers to advance protein and cell biology―breaking the barriers to novel, landmark discoveries. Devices’ StakMax® Microplate Stacker in a matter of minutes and . Catalog Number: (89212-396) Supplier: Molecular Devices. The introduction of the Molecular Devices’ SPECTRAmax PLUS microplate spectrophotometer marks the first time that photometric measurements made in a microplate format can be automatically normalized such that the resultant values are identical to those obtained with the corresponding solutions in a standard 1 cm pathlength cuvette. Select the Driver tab. Download PDF versions of the SpectraMax 190 User Guides and Installation Guides from Moleculardevices. 세포신호전달은 세포가 환경에 반응하고 다른 세포와 소통할 수 있게 합니다…. SpectraMax M3, M4, M5, and M5e Microplate Reader User Guide Cuvette Chamber The cuvette chamber is located to the right of the control panel. Integrated stacker and robot compatibility Molecular Devices offers the StakMax® Microplate Stacker for use with the SpectraMax L reader (Figure 3). Near bottom. #0200-7009) The SpectraMax® 340PC384 Reader from Molecular Devices provides everything needed to measure absorbance in the visible range, including temperature control, a robotics-compatible interface and SoftMax® Pro Data Acquisition and Analysis Software. The instrument is designed to regulate the temperature of the plate chamber from 5°C above ambient to 45°C. The UV-Vis SpectraMax 190 Microplate Reader for Quantification of DNA and endpoint, kinetic, and spectral scanning analyses. The FlexStation® 3 Multi-Mode Microplate Reader can be used to run the SpectraMax DuoLuc assay in 96- and 384-well formats with high sensitivity and throughput. Microplate readers. All stand-alone instrument functions can be controlled using the software. Mean background-subtracted RFU values are plotted for each transfection condition. Temperature: 4°C above ambient to. . The SPECTRAmax™ PLUS 384 microplate spectrophotometer provides rapid and sensitive UV/VIS measurements of a variety of analytes including specific proteins, nucleic acids, and other molecules across a wide range of concentrations. 0 nm increments . Here, the CVs for each plate were less than 3, and the difference between mean onset time for the plates run on the two readers was only 7%. #M5e) Methods Microplate reader compatibility test. Near bottom. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI). The SpectraMax ABS Plus reader utilizes Molecular Devices PathCheck® Sensor—the only patented technology available thatFeb 01, 2013. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Theseinstrumentsmeasuretheopticaldensity(OD)ofsamplesatselected wavelengthsinasinglereadmode. Plate stacker and robot integration The Gemini XPS Reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. 5 mm (bottom read) Beam diverges to focal spot near bottom of well. View the Molecular Devices website. The SpectraMax® Glo Steady-Luc™ Reporter Assay Kit provides a highly sensitive assay for the quantitation of firefly luciferase expression in mammalian cells. 5: 5. A 96-well plate scheme was selected for the measurement mode and the wells selected for targeting the respective colonies arrayed. Manufacturer: Molecular Devices Model: SpectraMax 190 “In working Condition. Molecular Devices announced today the launch of the new SpectraMax ® iD5 Multi-Mode Microplate Reader, a feature-rich platform that expands the boundaries of scientific research. Perform the following steps to install the drivers: Start > Control Panel > System. degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. 2. Figure 2. The SpectraMax® Mini multi-mode microplate reader offers a budget friendly solution that gives you exactly what you need when you need it. Sensitivity and dynamic range are demonstrated by the high Z’ factors obtained on the SpectraMax. Other technologies such as imaging. The SpectraMax ® iD5 Multi-Mode Microplate Reader is HTRF-certified, with an enhanced TRF detection module and filters optimized for HTRF detection. Double-click the unknown device with the yellow warning icon. Alpha Technology capability can be added to the system at any time as a user’s detection needs evolve. The SpectraMax 190 reader can be integrated with Molecular . PathCheck sensor corrects optical pathlength & pipetting variation. Optimal volumes are usually stated as 'working volume', which is 25 - 90 mL. The patented multichannel optical design of the SpectraMax® 190 Absorbance Microplate Reader mimics a dual beam spectrophotometer, measures each sample in the plate. 190-1000 nm, tunable in 1 nm increments. SpectraMax® 190 Absorbance Plate Reader, Molecular Devices Print… SpectraMax® 190 Absorbance Plate Reader, Molecular Devices. Expanded wavelength coverage. Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. Accurate quantitation The optical design of the SpectraMax 340PC384 reader truly mimics a dual. Cet appareil ISM est confomre à la norme NMB-001 du Canada. it is already turned on and the screen should look like this with “SpectraMax M5” showing as connected in the top left: 7. STAKMAX. The stability of the luminescent signal, as. Molecular Devices SpectraMax ® Paradigm ® Multi-Mode Microplate Detection Platform is a user upgradeable microplate reader that allows for real-time system configuration by the user in less than two minutes. 1. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. item 3 Molecular Devices SpectraMax 190 Microplate Spectrophotometer Molecular Devices SpectraMax 190 Microplate. On the FlexStation 3 reader, the entire series of reactions is monitored in real time with simultaneous on-board reagent pipetting and luminescence detection (Figure 1). With both kits, minimal increases in assay signal indicative of mycoplasma contamination can easily be detected. A UV/VIS microplate reader for DNA analysis and other life science applications, with PathCheck® sensor technology and spectral scanning. 2600A October 2023. The SpectraMax® ABS absorbance microplate readers bridge the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. For a higher . The top- and bottom-reading Gemini EM Microplate Reader with dual monochromators lets users determine the optimal excitation and emission settings for creative new fluorescence. Near bottom. Offer Ends In: 43 Days 20: 23: 11. There should be a value for 900 and 1000. 6% for the on-board optics (monochromators). . Both the MTT and Cell Cytotoxicity assays were read on the SpectraMax® ABS Plus Microplate Reader, which can read a 96-well microplate in less than 10 seconds. 41Hz for another 204 mS. The Spectramax 190 absorbance microplate reader utilizes a patented multichannel optical design to simulate a dual beam spectrophotometer to help eliminate errors. SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Fluorescence Microplate Reader Comparison Chart. 9000-0756. Description: This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with t. BioTek®/Agilent. 305 reference level saturation. The SpectraMax 190 reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. Our Price: $8,635. Molecular Devices’ SpectraMax i3x Multi-Mode Microplate Reader and Thermo Fisher Scientific’s Varioskan LUX reader also perform multiplexing. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. 7Hz for 204 mS and then at 29. Here is Molecular Devices SpectraMax M2 Multi-Mode Microplate Reader Unit3 Predecessor to: Current model Condition: This Molecular Devices SpectraMax. The following detection cartridge is required: • Fluorescence Polarization (FP-FLUO) Detection Cartridge (Molecular Devices cat. TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes acrossawiderangeofconcentrations. SpectraMax 190: N0: SpectraMax 250: S0: SpectraMax 340: M0: SpectraMax 340PC: L0: Gemini: G0: Gemini XS: XS0:. . The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. For a higher . SpectraMax® Gemini™ EM Microplate Reader, Molecular Devices. Microplate readers for sale and auction. begin reading microplates with seven mouse clicks. This reader also makes. The Gemini XPS can read a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well scan modes. The FlexStation® 3 Multi-Mode Microplate Reader can be used to run the SpectraMax DuoLuc assay in 96- and 384-well formats with high sensitivity and throughput. Figure 1. By measuring optical pathlength, it eliminates the last major distinction between microplate readers and spectrophotometers. #6590-0118) Filter 665/10 (Molecular Devices cat. #R8340) SpectraMax i3x Multi-Mode Microplate Reader (Molecular Devices cat. According to Biocompare, “one of the most overlooked pieces of equipment in any lab is the microplate reader. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. Select Start>Control panel>Device Manager. All stand-alone instrument functions can be controlled using the software. Learn more about how absorbance is measured, and some key applications that utilize. If no values are present, the water constant values are missing from the NVRAM. For a higher . #i3x) SpectraMax M5eMulti-Mode Microplate Reader (Molecular Devices cat. In addition, SoftMax Pro SoftwareWhat plates do you recommend for SpectraMax Plate Readers? Luminescence: Solid white plates for top reads and white plates with clear bottoms for bottom reads. The QuickSync client and automatic USB export option not only frees the user from waiting for data in front of the plate reader, but automatically sends it to one’s computer in an. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. The Gemini XPS Reader can be integrated with Molecular Devices’ StakMax ® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. New SpectraMax iD5 Multi-mode Microplate Reader. 5 - 2. 0 - 2. 190. 1. 5. , a leading provider of high-performance life science solutions and a company of Danaher Corporation (NYSE:DHR), has today. Microplate Reader Shelf. com. SpectraMax® Gemini™ EM Microplate Reader, Molecular Devices. 3. The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and. 1 in stock! Molecular Devices SpectraMax 384 Plus Microplate Reader Molecular Devices SpectraMax 384 Plus Microplate Reader Specifications. To purchase a newer software version,. However, this method is only able to measure down to about 250 ng/mL on a typical absorbance microplate reader. The Thermo max and UV Max readers use a different lamp. Page 27 SpectraMax M2 and M2e Microplate Reader User Guide Place a standard 1 cm cuvette that contains the aqueous/solvent mixture you use for the plate samples into the cuvette port. Luminescence . Simplify and expedite experiments with SoftMax Pro. Cell Biolabs OxiSelect Oxygen ORAC Activity Assay can be easily performed using the SpectraMax Gemini XPS Microplate Reader. Products : SoftMax Pro Software, SoftMax Pro GxP Software, CellReporterXpress software, General, Screenworks, pCLAMP/AxoScope, GenePix Pro, MetaXpress software. Figure 1. SpectraMax L Microplate Reader is a sensitive luminometer with programmable injector options that measures flash and glow. The ABS reader ranges from 340-850 nm in wavelength and the ABS Plus reader ranges from 190-1000 nm, which is equivalent to The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. The SpectraMax® ABS Plus Microplate Reader can run . used. Devices’ StakMax® Microplate Stacker in a matter of minutes and . For a higher . A. ATP concentration (M) Average RLU SpectraMax L SpectraMax i3x (cartridge) SpectraMax Mini SpectraMax iD5 SpectraMax i3x (onboard) SpectraMax M5eSPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual iii Labor and Parts To obtain warranty service during the applicable warranty period, you must take the product or de-liver the product properly packaged in the original shipping materials and carton to an authorized Molecular Devices Corporation service facility. 3. Title: SpectraMax i Series Multi-Mode Microplate Readers | Molecular Devices Author: Molecular Devices Subject: SpectraMax i Series offer the ideal solution for any application whether you are looking for an intuitive, easy-to-use reader, multi-user lab, or an upgradeable system that can adapt to support your lab s new projects. for the SpectraMax M3/M4 and FlexStation® 3 Multi-Mode Microplate Readers. The upgradeable SpectraMax M5 Multi-Mode Microplate Reader comes with the standard five modes of detection with the upgrade option to add HTRF at a later time. Molecular Devices Corporation Instrument Warranty Molecular Devices Corporation warrants this product against defects in material or workmanship as follows: 1) All parts of the SPECTRAmax PLUS Microplate Spectrophotometer are warranted for a period of one (1) year from the original date of delivery. Power tested, slide moves in and out of unit as. . SpectraMax® M4 Multi-Mode Microplate Reader MLDVM4 SpectraMax® M5 Multi-Mode Microplate Reader MLDVM5 SpectraMax® M5e Multi-Mode Microplate Reader (HTRF certified) MLDVM5E SpectraMax® Microplate Reader Suite of Products Knowledge Base. keeping with best practices, reader performance should. degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. displayed in each well of the microplate. The stability of the luminescent signal, as. Figure 2. 专为科研检测平台量身打造的灵活且强大的小型微孔板读板机(酶标仪),具备终点法和动力学检测模式,标准配置6块滤光片,覆盖蛋白定量、细胞活力、农药残留、ELISA实验等各种检测。. 2. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. microplate readers. The trademarks mentioned herein are the property of Molecular Devices, LLC or their respective owners. For more sample throughput, the system can• SpectraMax® Plus384 (Serial#-MNR-xxxxx) • SpectraMax® 340PC384 (Serial#-LNR-xxxxx) • SpectraMax® 190 (Serial#-NNR-xxxxx) •ersaMax™ (Serial#-BNR-xxxxx) V • AquaMax® Microplate Washer •ash™+ Microplate Washer MultiW. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. Setup Guide. We would like to show you a description here but the site won’t allow us. 5 - 2. Here we describe the use of Molecular Devices SpectraMax® Plus 384 Microplate Reader and SoftMax® Pro Software to efficiently collect and analyze the data for enzymatic determination of residual sugar in wine. Add to Cart. All the readers were operated using SoftMax® Pro Software, which also has built-in data analysis and curve-fitting for automatic calculation. For customers outside the U. follows simple plate reader prompts and the pre-defined analysis features get you to results quickly. This user guide provides detailed instructions, troubleshooting tips and technical specifications for these instruments. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. It features a dual-monochromator system, a large dynamic range, and a high-throughput capability. The SpectraMax 190 Reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. Devices’ StakMax® Microplate Stacker in a matter of minutes and . A. SpectraMax i3/i3x and Paradigm readers can be equipped with the HTRF detection cartridge. Microplate Readers. !Pathchecklm1000. We offer high quality refurbished lab equipment at affordable prices. 303 unable to cal dark current. Find regional support. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI). degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. Designed to provide the simplicity, flexibility and power required for advanced data analysis. Fluorescence Microplate Reader Comparison Chart. We would like to show you a description here but the site won’t allow us. Wypalls Paper Towel (Warehouse, Cat # 79300335 or equivalent) 7. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Preconfigured HTRF protocols in SoftMax ® Pro Software 7. TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes. The lamps for the Emax and Vmax microplate readers are 5 volt lamps. degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. Open the catalog to page 1. SpectraMax ® M2 Multi-Mode Microplate Reader. For more sample throughput, the system canThe SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. SpectraMax 190 Absorbance Microplate Reader by Molecular Devices®. Minimize sample volume while retaining sensitivity with the SpectraDrop Micro-Volume Microplate. The multi-channel design truly. microplate reader Handlers and accessories • Micro-volume detection for 1-64 samples • Elegant simplicity for multiuser labs • User versatility with different volume size and density options • Multi-channel pipettor can be used • Cleaning with hassle-free handling • Integrates with SpectraMax. 3 mm. The SpectraMax 190 reader can be integrated with Molecular . The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. This application note gives a basic procedure for optimization of excitation and emission wavelengths of the SPECTRAmax GEMINI microplate spectrophotometer. Absorbance Verification Plate (Molecular Devices, Cat # 0200-6117) 6. Lift up the lid over the chamber to insert or remove a cuvette. The SpectraMax 190 Microplate Reader is supplied with SoftMax Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software. This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. To update the driver. These models can no longer be repaired. 7Hz for 204 mS and then at 29. For biological applications involving small samples, such as purificationThe SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. View and Download Molecular Devices SPECTRAmax PLUS 384 operator's manual online. Download PDF. Wavelength Selection . com. Devices’ StakMax® Microplate Stacker in a matter of minutes and . 9000-0133 SpectraMax®MousePad. 2 485 views 4 years ago Molecular Devices SpectraMax 190 Microplate Reader is available from The Lab World Group. The SPECTRAmax™ PLUS 384 microplate spectrophotometer provides rapid and sensitive UV/VIS measurements of a variety of analytes including specific proteins, nucleic acids, and other molecules across a wide range of concentrations. 7°C and the bottom to 36. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. #0200-7030) Filter 320/100 (available from Molecular Devices) Filter 616/10 (Molecular Devices cat. Here, we illustrate how the SpectraMax iD5 reader, in combination with SoftMax ® Pro Software, is used to quantitate a cellular protein sample with two different kits, Pierce BCA Protein Assay Kit and Pierce Rapid. begin reading microplates with seven mouse clicks. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Products : SpectraMax i3x reader, SpectraMax iD5 reader, SpectraMax iD3 reader, General, FilterMax F5 reader, SpectraMax ABS reader, SpectraMax L reader, SpectraMax M5/M5e reader. The carriage moves back-and-forth at 19. For more sample throughput, the system canSpectramax Plus 384 Spectramax 190 Spectramax 340PC384 Versamax Microplate Spectrophotometers; A Fluorescence Correlation Spectrometer for Measurements in Cuvettes; Spectramax Plus 384 Microplate Reader | Molecular Devices; CA-800 Brochure; Eppendorf Tube Rack/Eppendorf Cuvette Rack English (EN) Commonly. begin reading microplates with seven mouse clicks. Designed to provide the simplicity, flexibility and power required for advanced data analysis. Calcein AM is a widely used live-cell marker. Both readers feature an 8-channel read head for fast reads and a subset feature, the temperature independent PathCheck sensor that. 00. The shake motion is linear back-and-forth, so there is no measure of RPM. 1step assay with SpectraMax microplate readers. . NOTE: Limited support and literature is available for the SpectraMax 250 due to the senescence of the product. SpectraMax 250 User. At that point halfway up the maximum transmittance value, the total width (nm) of the transmitted band is. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Set up assay plate . Molecular Devices Spectramax iD3 Microplate Reader. begin reading microplates with seven mouse clicks. SpectraMax Gemini EM & FLEXstation (bottom read) 1. View the LabX ads below to find Molecular Devices SpectraMAX plate readers for sale and auction. Accurate quantitation The optical design of the SpectraMax 340PC384 reader truly mimics a dual-beam microplate readers. In addition, SoftMax Pro SoftwareWhat plates do you recommend for SpectraMax Plate Readers? Luminescence: Solid white plates for top reads and white plates with clear bottoms for bottom reads. The Molecular Devices SpectraMAX absorbance microplate readers mimic a dual beam spectrophotometer with a patented multichannel optical design. You can also contact Technical Support by email. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. With optimized reagents and the industryleading data acquisition and analysis tool, SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. San Jose, Calif.